Must-Read for Electroplating Plant Owners! 3-Minute Self-Check Guide to Combat Burner "Corrosion Killers" - Save Thousands in Annual Maintenance Costs_Foshan Shunde Zhibo Burner Manufacturing Co., Ltd.

  • 深夜免费视频网站,深夜福利在线播放,深夜视频成人版下载,深夜福利APP污污软件大全

    Home > Company News

    Must-Read for Electroplating Plant Owners! 3-Minute Self-Check Guide to Combat Burner "Corrosion Killers" - Save Thousands in Annual Maintenance Costs

    Time:2025-04-24 Click:

    Longevity Secrets for Your Electroplating Burner: 3 High-Risk Component Inspection Methods:

    一、External Inspection (Completed in 3 Minutes)

    1️⃣ Burner Housing Surface  
    ✔️ Check: Peeling coating/rust/discoloration  
    ⚠️ Standard: No rust, intact coating  
    🔧 Tools: Visual inspection + flashlight  

    2️⃣ Pipe Connections
    ✔️ Check: Leaks/rust at flanges/threads  
    ⚠️ Standard: Tight seals, no corrosion  
    🔧 Tools: Wipe with tissue paper  

    3️⃣ Exhaust Outlet
    ✔️ Check: Carbon buildup/acidic condensate on inner walls  
    ⚠️ Standard: No sticky corrosive residue  
    🔧 Tools: Endoscope (optional)




    二、Core Internal Inspection (Requires Shutdown)

    🔥 Combustion Chamber Refractory Layer
    ✔️ Check: Cracks/spalling in refractory material 
    ❗ Risk:Acidic gases accelerate erosion!
     🔧 Method: Tap to listen for hollow sounds (indicates damage) 

    🌀 Heat Exchanger Fins
    ✔️ Check: Acid mist condensate/corrosion holes  
    🔧 Method: Clean with soft brush + compressed air

    ⚡ Electrodes & Igniter Plates
    ✔️ Check: Ceramic insulator cracks/metal oxidation  
    🔧 Tools: Multimeter to test insulation resistance 




    三、Electroplating Workshop-Specific Checks  

    ⚠️ Acid/Alkali Gas Protection 
    ✔️ Action: Test ambient air around equipment with pH test paper  
    🔌 Grounding Resistance Test 
    ✔️ Standard: Grounding resistance ≤4Ω  




    四、Emergency Response

    ⛔Immediately Shut Down the Machine if the Following Issues are Detected: 
    → Perforated heat exchanger fins  
    → Large-area spalling in combustion chamber refractory layer  
    → Electrode/ion rod insulation resistance <10MΩ  


    ⏰ Pro Tip:Perform these checks monthly to extend burner lifespan by 2-3 years and slash maintenance costs! 